SERVICE PROGRAM TABLES August, 2006
5-186
Group 9000
9405 System Stop Ctrl
Setting
Setting of the System Stop Control Function.
001 System Stop Control
ON/OFF
Switches the System Stop Control Function ON
or OFF.
When this switch is ON:
The machine stops the job when the output of the
temperature/humidity sensor on the K-PCU is
41°C (105.8F) or higher.
Note: This keeps the temperature of the toner in
the development unit below 50°C (122F), which
prevents toner clumping and other machine
failures.
[0 - 1/ 1] 0: OFF , 1: ON (default)
002 System Stop History Displays whether or not System Stop Control has
ever stopped the machine in the middle of the
job.
0 (default): System Stop Control has never
stopped the machine.
1: System Stop Control has stopped the machine
one or more times.