April, 2007 SERVICE CALL CONDITIONS
4-71
SC900: Miscellaneous
Electrical total counter error
SC900
D
The total counter contains
something that is not a number.
NVRAM incorrect type
NVRAM defective
NVRAM data scrambled
Unexpected error from external source
SC910 External controller (E-7000) error 1
SC911 External controller (E-7000) error 2
SC912 External controller (E-7000) error 3
SC913 External controller (E-7000) error 4
B
The external controller (E-7000) sends
an error message.
Turn the machine power
OFF/ON
External controller (E-7000) error 5 SC914 B
The external controller (E-7000) sends
an error message.
Turn the machine power
OFF/ON
External controller (E-7000) down SC919
D
The EAC received an interrupt signal
from the FLUTE serial driver during
print jobs in progress and the
connection between the copier and
external controller (E-7000) was
broken.
Note: The EAC is the External Api
Converter.
Switch the machine OFF and ON.
Printer error 1
SC920
B
An internal application error was
detected and operation cannot
continue.
Software defective; turn the machine
OFF/ON, or change the controller
firmware
Insufficient memory
Printer error 2
SC921
B
When the application started, the
necessary font was not on the SD
card.
Font not on the SC card