EasyManua.ls Logo

Toshiba e-STUDIO4500c - Appendix

Toshiba e-STUDIO4500c
1120 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
April, 2007 ADDITIONAL INFORMATIONS
4-99
APPENDIX:
Default settings of SP modes related to previous Temporary Solutions A, B and B+
SP
Number
Description
Default
Settings
NOTE
1105-003 Htg Roll Sn1: Ctr
Wait Temp: Norm
177 deg Heating Roller Temperature in Standby
mode.
1105-006 Htg Roll Sn1: Ctr
1-S: Norm: 1 Col
175 deg Heating Roller Temperature for normal
paper simplex 1C.
1105-007 Htg Roll Sn1:Ctr
1-S:Norm:FC
175 deg Heating Roller Temperature for normal
paper simplex FC.
1105-008 Htg Roll Sn1:Ctr
1-S: Trace:1C
160 deg Heating Roller Temperature for thin paper
simplex 1C
1105-009 Htg Roll Sn1: Ctr
1-S: Trace: FC
160 deg Heating Roller Temperature for thin paper
simplex FC
1105-014 Htg: Roll Sn1: Ctr
2-S: Norm: 1C
175 deg Heating Roller Temperature for normal
paper duplex 1C
1105-015 Htg: Roll Sn1: Ctr
2-S: Norm: FC
175 deg Heating Roller Temperature for normal
paper duplex FC
1105-016 Htg: Roll Sn1: Ctr
2-S: Trace: 1C
160 deg Heating Roller Temperature for thin paper
duplex 1C.
1105-017 Htg: Roll Sn1:Ctr
2-S: Trace: FC
160 deg Heating Roller Temperature for thin paper
duplex FC.
1105-029 PressRoll Sensor
Wait Temp: Norm
152 deg Pressure Roller Temperature for Stand-by
mode.
1107-007 Mode Shift
Press Temp: Norm
5 deg Additional Temperature for heating roller at
the start of print job.
1107-008 Mode Shift
Press Time: Norm
10 sec Additional Temperature applying time for
heating roller at the start of print job.
1107-015 To Cooling Mode
Trace Cool End
5 Copy/Print job starts when the heating
roller temperature reaches the setting
temperature plus this value.
1108-008 Htg Roll Lamp2
Norm: FC
83 Heating Roller Lamp2 duty for FC printing
1108-009 Htg Roll Lamp2
Scan: Norm: FC
66 Heating Roller Lamp2 duty for FC scanning
and printing.
1108-017 Htg Roll Lamp2
At Reload
27 Heating Roller Lamp2 duty during machine
warming up.
9406-001 Fan Op Temp 0 Cooling fan full rotation
0: default (32C)
1: 30C
2: 28C

Table of Contents

Other manuals for Toshiba e-STUDIO4500c

Related product manuals