August, 2006 SERVICE PROGRAM TABLES
5-109
5162 App. Switch Method
Controls if the application screen is changed with a hardware switch or a software
switch.
[0~1/1]
0: Soft Key Set
1: Hard Key Set
5169 CE Login
If you will change the printer bit switches, you must ‘log in’ to service mode with this SP
before you go into the printer SP mode.
[0~1/1]
0: Off. Printer bit switches cannot be adjusted.
1: On. Printer bit switches can be adjusted.
5212 Page Numbering
003 Duplex Printout Left/Right Position Horizontally positions the page numbers
printed on both sides during duplexing.
[–10~+10/1 mm]
0 is center, minus is left, + is right.
004 Duplex Printout High/Low Position Vertically positions the page numbers
printed on both sides during duplexing.
[–10~+10/1 mm]
0 is center, minus is down, + is up.
5302 Set Time DFU
Sets the time clock for the local time. This setting is done at the factory before
delivery. The setting is GMT expressed in minutes.
[–1440~1440/1 min.]
JA: +540 (Tokyo)
NA: -300 (NY)
EU: +6- (Paris)
CH: +480 (Peking)
TW: +480 (Taipei)
AS: +480 (Hong Kong)

Table of Contents