SERVICE PROGRAM TABLES August, 2006
5-112
023 Door Operation: Time
Length
Determines what happens when the front door remains
open.
[0~1/1]
0: Automatic Call
1: Audible Warning at Machine
Parts Alarm Level Count Japan Only
001 Normal Sets the parts replacement alarm counter to
sound for the number of copies.
[1~999/1 K]
5513
002 DF Sets the parts replacement alarm counter to
sound for the number of scanned originals.
[1~999/1 K]
5514 Parts Alarm Level Japan Only
001 Normal
002 DF
5610 ACC Factory Setting DFU
004
Adjusts the toner ratio between color pairs: Black, Cyan, Magenta, Green, and
Yellow.
001