TX2560 M2 / RX2560 M2 Upgrade and Maintenance Manual
561
Appendix
I Note on CSS and Global Error indicators on the I/O panel
If CSS and Global Error indicators are located in the same place on your
server’s I/O panel, please also check the indicators on the front panel to
determine if a CSS or Global Error event has been detected.
I
For further details on detected errors, refer to the System Event Log
(SEL) or use the ServerView Operations Manager or iRMC S4 web
interface.
1
Global Error
indicator,
see also
"iRMC-
related
status
signals" on
page 562
off
No critical event detected (non CSS
component).
orange on
Prefailure event detected (non CSS
component).
orange
flashing
Non CSS component failure
detected.
Possible causes:
System is out of the specified
temperature range
Defective sensor
CPU error
Error detected by server
management software
2
[CSS]
CSS
indicator
off
No critical event detected (CSS
component).
orange on
Prefailure event detected (CSS
component).
For HDDs see also "HDD
prefailure detection" on page 562
orange
flashing
CSS component failure detected.
Pos. Label Indicator Status Description
!