Command Manual - QoS/ACL
Quidway S3500 Series Ethernet Switches Chapter 1 ACL Commands
Huawei Technologies Proprietary
1-25
Parameter
time-name: Name of a special time range to be referenced.
start-time: Start time of the special time range, format as hh:mm.
end-time: End time of the special time range, format as hh:mm.
days-of-the-week: Determines in which day(s) of a week in the special time range a
command takes effect. You can specify this parameter with any of the following values.
Numbers (ranging from 0 to 6);
Monday, Tuesday, Wednesday, Thursday, Friday, Saturday or Sunday;
working-day, representing 5 working days, from Monday to Friday;
off-day, representing Saturday and Sunday;
daily, representing everyday of the week.
from start-time start-date: Start time and date of the special time range, determining
effective days of the time range with the end-date, format as hh:mm MM-DD-YYYY.
to end-time end-date: End time and date of the special time range, determining
effective days of the time range with the start-date, format as hh:mm MM-DD-YYYY.
If the above two parameters are omitted, there is no limit to the effective date.
Description
Using time-range command, you can configure a time range. Using undo time-range
command, you can delete a time range.
If you input the parameter when use the undo time-range command, the system will
delete the corresponding content of the time range according to the parameter input.
Example
# Configure a time range being effective since zero hour on January 1, 2000 and
forever.
[Quidway] time-range test from 0:0 1-1-2000
1.3 ACL Configuration Command List of S3552 Series
Switches
S3552 Series Ethernet Switches include S3552G, S3552P, S3528G, and S3528P
Ethernet Switches.
1.3.1 acl
Syntax
acl { number acl-number | name acl-name [advanced | basic | link ] } [ match-order
{ config | auto } ]