Command Manual - System Management
Quidway S3500 Series Ethernet Switches Chapter 3 Device Management Commands
Huawei Technologies Proprietary
3-6
Description
Using reboot command, you can reset the Ethernet Switch when failure occurs.
Example
# Reboots the Switch.
<Quidway> reboot
3.1.9 temperature-limit
Syntax
temperature-limit slot-num down-value up-value
undo temperature-limit slot-num
View
User view, system view
Parameter
slot-num: Physical card number, for S3552 series, the value is 0.
down-value: Lower temperature limit, ranging from 0 to 45, unit in ℃.
up-value: Upper temperature limit, ranging from 50 to 80, unit in℃.
Description
Using temperature-limit command, you can configure temperature limit. Using undo
temperature-limit command, you can restore temperature limit to default value.
Example
# Set the lower and upper temperature limit.
<Quidway> temperature-limit 0 10 75