Quidway S3500 Series Ethernet Switches Chapter 1 Ethernet Port Configuration Commands
Huawei Technologies Proprietary
1-13
Using this command in the system, you can enable/disable the port loopback detection
function of the entire device; using this command in Ethernet port view, you can
enable/disable the port loopback detection function of the current port.
By default, port loopback detection is enabled.
For the related command, see display loopback-detection.
Example
# Enable the port loopback detection.
[Quidway] loopback-detection enable
1.1.15 loopback-detection interval-time
Syntax
loopback-detection interval-time time
undo loopback-detection interval-time
View
System view
Parameter
time: Specifies the interval of monitoring external loopback conditions of the port. It
ranges from 5 to 300, measured in seconds. By default, the interval is 30 seconds.
Description
Using loopback-detection interval-time command, you can configure detection
interval for the external loopback condition of each port. Using undo
loopback-detection interval-time command, you can restore the default interval.
For the related command, see display loopback-detection.
Example
# Configure the detection interval for the external loopback condition of each port to 10
seconds.
[Quidway] loopback-detection interval-time 10
1.1.16 loopback-detection per-vlan enable
Syntax
loopback-detection per-vlan enable
undo loopback-detection per-vlan enable