Command Manual - Integrated Management
Quidway S3500 Series Ethernet Switches Chapter 2 HGMP V2 Configuration Commands
Huawei Technologies Proprietary
2-31
2.3.20 timer
Syntax
timer interval-in-secs
undo timer
View
Cluster view
Parameter
Interval-in-secs: This parameter is to set sending time interval of the handshake packet,
ranging of 1 ~ 255 seconds. By default ,the value is 10 seconds.
Description
Using timer command, you can configure the interval of handshake packets. Using
undo timer command, you can restore the default value of the interval.
Inside a cluster, the member devices communicate with the administrator device
through transmitting handshake packets. The regular handshake can help the user
monitor the states of cluster members and links.
This command can only be executed on the administrator device, which will advertise
the cluster timer value to the member devices.
Example
# Configure to send handshake packets once every 3 seconds.
[Huawei_0.Quidway-cluster] timer 5