Command Manual - Security
Quidway S3500 Series Ethernet Switches Chapter 3 AAA & RADIUS Protocol Configuration Commands
Huawei Technologies Proprietary
3-41
Example
# Set the response timeout timer of RADIUS scheme, huawei, to 5 seconds.
[Quidway-radius-huawei] timer 5
3.2.26 timer quiet
Syntax
timer quiet minutes
undo timer quiet
View
RADIUS scheme view
Parameter
minutes: Quiet time interval, ranging from 1 to 255, in minutes. The default value is 5.
Description
Use the timer quiet command to set the quiet time interval after which the primary and
secondary RADIUS servers switch over.
Use the undo timer quiet command to set the quiet time interval to its default value.
The functions of the quiet time interval are as follows:
z The switch sends RADIUS packets to the primary RADIUS server.
z If the switch affirms that the primary server does not respond, it then sends
RADIUS packets to the secondary RADIUS server.
z After each quiet time interval, the switch sets the status of the primary RADIUS
server to active, and sends RADIUS packets to it next time.
Among S3500 series ethernet switches, S3552G, S3552P, S3528G, S3528P, S3526E,
S3526E FM, S3526E FS and S3526C support this function, and S3526, S3526 FM and
S3526 FS don’t.
Example
# Set the quiet time interval of the RADIUS server group “huawei” to 3 minutes.
[Quidway] radius scheme huawei
[Quidway-radius-huawei] timer quiet 3
3.2.27 timer realtime-accounting
Syntax
timer realtime-accounting minute
undo timer realtime-accounting