Command Manual - System Management
Quidway S3500 Series Ethernet Switches Chapter 4 System Maintenance Commands
Huawei Technologies Proprietary
4-1
Chapter 4 System Maintenance Commands
4.1 Basic System Configuration and Management
Commands
4.1.1 clock datetime
Syntax
clock datetime HH:MM:SS YYYY/MM/DD
View
User view
Parameter
HH:MM:SS: Current clock. HH ranges from 0 to 23. MM and SS range from 0 to 59.
YYYY/MM/DD: Specify the current year, month and date. YYYY ranges from 1993 to
2035. MM ranges from 1 to 12 and DD ranges from 1 to 31.
Description
Using clock datetime command, you can configure the current date and clock of
Ethernet Switch.
By default, the date and clock of Ethernet Switch is set as 0:0:0, 2000/1/1.
The current date and clock of Ethernet Switch must be set in the circumstance that
absolute time is strictly required.
For the related commands, see display clock.
Example
# Set the current date of Ethernet Switch to 0:0:0, 2001/01/1.
<Quidway> clock datetime 0:0:0 2001/01/01
4.1.2 clock summer-time
Syntax
clock summer-time zone_name { one-off | repeating } start-time start-date end-time
end-date offset-time
undo clock summer-time

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei quidway s3526 series and is the answer not in the manual?

Huawei quidway s3526 series Specifications

General IconGeneral
BrandHuawei
Modelquidway s3526 series
CategoryNetwork Router
LanguageEnglish

Related product manuals