EasyManua.ls Logo

NXP Semiconductors PXN2020 - 26.5.2.47 Slot Status Counter Registers (SSCR0-SSCR3)

NXP Semiconductors PXN2020
1376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FlexRay Communication Controller (FlexRAY)
PXN20 Microcontroller Reference Manual, Rev. 1
26-54 Freescale Semiconductor
26.5.2.47 Slot Status Counter Registers (SSCR0–SSCR3)
Each of these four registers provides the slot status counter value for the previous communication cycle(s)
and is updated at the cycle start. The provided value depends on the control bits and fields in the related
internal slot status counter condition register SSCCRn, which can be programmed by using the Slot Status
Counter Condition Register (SSCCR). For more details, see Section 26.6.18.4, Slot Status Counter
Registers.
VFA Valid Frame on Channel A — protocol related variable: vSS!ValidFrame channel A
0 vSS!ValidFrame = 0.
1 vSS!ValidFrame = 1.
SYA Sync Frame Indicator Channel A — protocol related variable: vRF!Header!SyFIndicator channel A
0 vRF!Header!SyFIndicator = 0.
1 vRF!Header!SyFIndicator = 1.
NFA Null Frame Indicator Channel A — protocol related variable: vRF!Header!NFIndicator channel A
0 vRF!Header!NFIndicator = 0.
1 vRF!Header!NFIndicator = 1.
SUA Startup Frame Indicator Channel A — protocol related variable: vRF!Header!SuFIndicator channel A
0 vRF!Header!SuFIndicator = 0.
1 vRF!Header!SuFIndicator = 1.
SEA Syntax Error on Channel A — protocol related variable: vSS!SyntaxError channel A
0 vSS!SyntaxError = 0.
1 vSS!SyntaxError = 1.
CEA Content Error on Channel A — protocol related variable: vSS!ContentError channel A
0 vSS!ContentError = 0.
1 vSS!ContentError = 1.
BVA Boundary Violation on Channel A — protocol related variable: vSS!BViolation channel A
0 vSS!BViolation = 0.
1 vSS!BViolation = 1.
TCA Transmission Conflict on Channel A — protocol related variable: vSS!TxConflict channel A
0 vSS!TxConflict = 0.
1 vSS!TxConflict = 1.
Base + 0x0078 (SSCR0)
Base + 0x007A (SSCR1)
Base + 0x007C (SSCR2)
Base + 0x007E (SSCR3)
Additional Reset: RUN Command
0123456789101112131415
R SLOTSTATUSCNT
W
Reset0000000000000000
Figure 26-47. Slot Status Counter Registers (SSCR0–SSCR3)
Table 26-55. SSR0–SSR7 Field Descriptions (continued)
Field Description

Table of Contents

Related product manuals