April, 2007 SERVICE PROGRAM TABLES
5-27
011
Fuse Exit Temp The temperature used to calculate the temperature
specified for the hot roller at the end of fusing/exit motor
rotation when the warmup temperature has been reached.
[0~30/1 deg. ]
012
Add Rot Time The amount of time added to the rotation time of the
fusing/exit motor after warmup temperture has been
reached, based on the temperature specified for the hot
roller at standby.
[0~90/10 sec.]
Stand Cool On/Off Standby Ventilation Cooling: On/Off
013
Thk2 (0:Off 1:On) Switches ON/OFF standby for cooling after printing thick
paper.
0: Off 1: On
To Cooling Mode Standby Ventilation Cooling: Setting
014
Thk2/OHP Cool End Sets the temperature to end the cool down period after
printing with thick paper or OHP.
[0~40/1 deg. ]
015
Trace Cool End Sets the temperature to end the cool down period after
printing with tracing (thin) paper.
[0~40/1 deg. ]
Edge Cool On/Off Standby Ventilation Cooling: On/Off High Edge Temp.
016
Start (0:No 1:Yes) Switches ON/OFF standby for cooling for the ends of the
fusing rollers after printing on wide paper.
0: Off 1: On

Table of Contents

Other manuals for Toshiba e-STUDIO4500c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba e-STUDIO4500c and is the answer not in the manual?

Toshiba e-STUDIO4500c Specifications

General IconGeneral
BrandToshiba
Modele-STUDIO4500c
CategoryAll in One Printer
LanguageEnglish

Related product manuals