S2VNA and S4VNA SCPI Programming Manual
282
SENS:CORR:EXT:AUTO:CONF
SENSe
<Ch>
:CORRection:EXTension:AUTO:CONFig {CSPN|AMKR|USPN}
SENSe
<Ch>
:CORRection:EXTension:AUTO:CONFig?
Description
Specifies the frequency range used for calculation of the results of
the Auto Port Extension function.
(command/query)
Target
The active trace of channel <Ch>,
<Ch>={[1]|2|...16}
Parameter
CSPN : Uses current frequency span
AMKR : Uses the frequency of the active marker. This is applied to
Loss 1 and Loss 2 is ignored.
USPN : Uses arbitrary frequency range set by user
Query Response
{CSPN|AMKR|USPN}
Preset Value
CSPN
Equivalent Softkeys
Calibration > Port Extension > Auto Port Extension > Method {Current
span | Acive Marker | User Span}