EasyManua.ls Logo

Copper Mountain Technologies S2 Series - Calc:par:coun

Copper Mountain Technologies S2 Series
428 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
S2VNA and S4VNA SCPI Programming Manual
72
CALC:PAR:COUN
CALCulate
<Ch>
:PARameter:COUNt
<numeric>
CALCulate
<Ch>
:PARameter:COUNt?
Description
Sets or reads out the number of traces in the channel.
(command/query)
Target
The channel <Ch>={[1]|2|...16}
Parameter
<numeric> The number of the traces in the channel from 1 to 16
Out of Range
Sets the value of the limit, which is closer to the specified value.
Query Response
<numeric>
Preset Value
1
Equivalent Softkeys
Display > Num of Traces