Maintenance and Troubleshooting
674
M4300 Series and M4300-96X Fully Managed Switches User Manual
3. Enter the user name and password.
The default admin user name is admin and the default admin password is blank, that is,
do not enter a password.
4. Click the Login button.
The System Information page displays.
5. Select Maintenance > T
roubleshooting > T
raceroute IPv4.
6. Use IP Address/Hostname to enter the IP address or host name of the station to which you
want to discover a path.
The default value is blank.
7. Enter the number of Probes Per Hop.
The default value is 3. The range is 1 to 10.
8. Enter the Maximum TTL for the destination.
The default value is 30. The range is 1 to 255.
9. Enter the Initial TTL to be used.
The default value is 1. The range is 1 to 255.
10. Enter the Maximum Failures allowed in the session.
The default value is 5. The range is 1 to 255.
11. Interval (secs). Enter the time between probes in seconds.
The default value is 3. The range is 1 to 60.
12. Enter the UDP Destination Port in probe packets.