14. Use the Offset Hours field to specify the number of hours of difference from UTC. 
The allowed range is –12 to 13. The default value is 0.
15. Use the Offset Minutes field to specify the number of minutes of difference from UTC. 
The allowed range is 0 to 59. 
The default value is 0.
16. Click the Apply button.
Your settings are saved.
View SNTP Global Status
When you select the SNTP option as the Clock Source, the SNTP global status is displayed 
below the SNTP Global Configuration section of the page.
 To view SNTP global status:
1.  Launch a web browser.
2.  In the address field of your web browser, enter the IP address of the switch.
The login window opens.
3.  Enter the user name and password. 
The default admin user name is 
admin and the default admin password is blank, that is, 
do not enter a password.
4.  Click the Login button. 
The System Information page displays.
5.  Select System > Management > T
ime > T
ime Configuration > SNTP Global Status
6.  Select the SNTP option as the Clock Source.