LH79524/LH79525 User’s Guide Vectored Interrupt Controller
Version 1.0 18-9
18.2.2.6 Interrupt Enable Clear Register (INTENCLEAR)
This register clears the individual bits in the INTENABLE Register. Bits [31:0] correspond
to the interrupt number in Table 18-1.
Table 18-13. INTENCLEAR Register
BIT 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
FIELD IntEnable Clear
RESET 0000000000000000
RW WO WO WO WO WO WO WO WO WO WO WO WO WO WO WO WO
BIT 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
FIELD IntEnable Clear
RESET 0000000000000000
RW WO WO WO WO WO WO WO WO WO WO WO WO WO WO WO WO
ADDR 0xFFFFF000 + 0x014
Table 18-14. INTENCLEAR Fields
BITS NAME DESCRIPTION
31:0 IntEnable Clear
Clear IntEnable Bit Clears bits in the INTENABLE Register.
For each bit:
1 = Clears the corresponding bit in the IntEnable Register