Timers LH79524/LH79525 User’s Guide
15-24 Version 1.0
15.2.2.15 Timer 2 Interrupt Control Register (INTEN2)
This register allows software to enable and disable individual interrupts as needed.
Table 15-32. INTEN2 Register
BIT 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
FIELD ///
RESET 0000000000000000
RW RO RO RO RO RO RO RO RO RO RO RO RO RO RO RO RO
BIT 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
FIELD ///
CAPB_EN
CAPA_EN
CMP1_EN
CMP0_EN
OVF_EN
RESET 0000000000000000
RW RO RO RO RO RO RO RO RO RO RO RO RW RW RW RW RW
ADDR 0xFFFC4000 + 0x54
Table 15-33. INTEN2 Register Definitions
BITS NAME DESCRIPTION
31:5 /// Reserved Reading this field returns 0. Write the reset value.
4 CAPB_EN
Timer 2 Interrupt Enable During Capture B Operation
1 = Interrupt enabled for capture B
0 = Interrupt disabled for capture B
3 CAPA_EN
Timer 2 Interrupt Enable During Capture A Operation
1 = Interrupt enabled for capture A
0 = Interrupt disabled for capture A
2CMP1_EN
Timer 2 Interrupt Enable Upon Compare 1
1 = Interrupt enabled for compare 1
0 = Interrupt disabled for compare 1
1 CMP0_EN
Timer 2 Interrupt Enable Upon Compare
1 = Interrupt enabled for compare 0
0 = Interrupt disabled for compare 0
0OVF_EN
Timer 2 Interrupt Overflow Enable
1 = Interrupt enabled for counter overflows
0 = Interrupt disabled for counter overflows