C613-50055-01 REV A Command Reference for x230 Series Edge Switches 1157
AlliedWare Plus™ Operating System - Version 5.4.5-0.x
EPSR COMMANDS
SHOW
EPSR CONFIG-CHECK
show epsr config-check
Overview This command checks the configuration of a specified EPSR instance, or all EPSR
instances.
If an instance is enabled, this command will check for the following errors or
warnings:
The control VLAN has the wrong number of ports.
There are no data VLANs.
Some of the data VLANs are not assigned to the ring ports.
The failover time is less than 5 seconds, for a stacked device.
The instance is a master that shares a common segment with a higher
priority instance.
The instance is a master that shares a common segment with another
master.
The instance is a master with its secondary port on a common segment.
Syntax
show epsr [<instance>] config-check
Mode User Exec and Privileged Exec
Example To check the configuration of all EPSR instances and display the results, use the
command:
awplus# show epsr config-check
Parameter Description
<instance> Name of the EPSR instance to check on.
Table 34-5: Example output from the show epsr config-check command
EPSR Status Description
Instance
--------------------------------------------------------------------------------
red Warning Failover time is 2s but should be 5s because device.
is stacked
white OK.
blue Warning Primary port is not in data VLANs 29-99.
orange OK.
Don't forget to check that this node's configuration is consistant with all
other nodes in the ring.
--------------------------------------------------------------------------------