C613-50055-01 REV A Command Reference for x230 Series Edge Switches 1157
AlliedWare Plus™ Operating System - Version 5.4.5-0.x
EPSR COMMANDS
SHOW
EPSR CONFIG-CHECK
show epsr config-check
Overview This command checks the configuration of a specified EPSR instance, or all EPSR
instances.
If an instance is enabled, this command will check for the following errors or
warnings:
• The control VLAN has the wrong number of ports.
• There are no data VLANs.
• Some of the data VLANs are not assigned to the ring ports.
• The failover time is less than 5 seconds, for a stacked device.
• The instance is a master that shares a common segment with a higher
priority instance.
• The instance is a master that shares a common segment with another
master.
• The instance is a master with its secondary port on a common segment.
Syntax
show epsr [<instance>] config-check
Mode User Exec and Privileged Exec
Example To check the configuration of all EPSR instances and display the results, use the
command:
awplus# show epsr config-check
Parameter Description
<instance> Name of the EPSR instance to check on.
Table 34-5: Example output from the show epsr config-check command
EPSR Status Description
Instance
--------------------------------------------------------------------------------
red Warning Failover time is 2s but should be 5s because device.
is stacked
white OK.
blue Warning Primary port is not in data VLANs 29-99.
orange OK.
Don't forget to check that this node's configuration is consistant with all
other nodes in the ring.
--------------------------------------------------------------------------------