C613-50055-01 REV A Command Reference for x230 Series Edge Switches 521
AlliedWare Plus™ Operating System - Version 5.4.5-0.x
POWER OVER ETHERNET COMMANDS
SHOW
POWER-INLINE
show power-inline
Overview This command displays the Power over Ethernet (PoE) status for all ports on the
Power Sourcing Equipment (PSE).
For information on filtering and saving command output, see “Controlling “show”
Command Output” in the “Getting Started with AlliedWare Plus” Feature Overview
and Configuration Guide.
Syntax
show power-inline
Mode User Exec and Privileged Exec
Example To display the PoE status for all ports on the PSE, use the following command:
awplus# show power-inline
Table 14-1: Parameters in the show power-inline command output
Parameter Description
Nominal Power The nominal power available on the switch in watts (W).
Power Allocated The current power allocated in watts (W) that is available to
be drawn by any connected Powered Devices (PDs). This is
updated every 5 seconds.
Actual Power
Consumption
The current power consumption in watts (W) drawn by all
connected Powered Devices (PDs). This is updated every 5
seconds.
Operational
Status
The operational status of the PSU hardware on the PSE
when this command was issued:
• On if the PSU as installed inside the PSE is switched on.
• Off when the PSU in the PSE is switched off (an RPS may
be connected to the PSE to power PoE instead of the
PSU).
• Fault when there is an issue with the PSE PSU hardware.
Power Usage
Threshold (%)
The configured SNMP trap / log threshold for the PSE, as
configured from a power-inline usage-threshold
command.
Interface The PoE port(s) in the format portx.y.z, where x is the
device number, y is the module number within the device,
and z is the PoE port number within the module.
Admin The administrative state of PoE on a PoE port, either
Enabled or Disabled.