826 Command Reference for x230 Series Edge Switches C613-50055-01 REV A
AlliedWare Plusâ„¢ Operating System - Version 5.4.5-0.x
802.1X COMMANDS
DOT
1X TIMEOUT TX-PERIOD
dot1x timeout tx-period
Overview This command sets the transmit timeout for the authentication request on the
specified interface.
The no variant of this command resets the transmit timeout period to the default
(30 seconds).
Syntax
dot1x timeout tx-period <1-65535>
no dot1x timeout tx-period
Default The default transmit period for port authentication is 30 seconds.
Mode Interface Configuration for a static channel, a dynamic (LACP) channel group, or a
switch port.
Usage Use this command to set the interval between successive attempts to request an
ID.
Examples To set the transmit timeout period to 5 seconds on interface port1.0.2, use the
commands:
awplus# configure terminal
awplus(config)# interface port1.0.2
awplus(config-if)# dot1x timeout tx-period 5
To reset transmit timeout period to the default (30 seconds) on interface
port1.0.2, use the commands:
awplus# configure terminal
awplus(config)# interface port1.0.2
awplus(config-if)# no dot1x timeout tx-period
Validation
Commands
show dot1x
show dot1x interface
Parameter Description
<1-65535> Seconds.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus AT-x230-10GP and is the answer not in the manual?

Allied Telesis AlliedWare Plus AT-x230-10GP Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus AT-x230-10GP
CategorySwitch
LanguageEnglish

Related product manuals