C613-50055-01 REV A Command Reference for x230 Series Edge Switches 451
AlliedWare Plusâ„¢ Operating System - Version 5.4.5-0.x
SPANNING TREE COMMANDS
SPANNING
-TREE ERRDISABLE-TIMEOUT ENABLE
spanning-tree errdisable-timeout enable
Overview Use this command to enable the errdisable-timeout facility, which sets a timeout
for ports that are disabled due to the BPDU guard feature.
Use this command for RSTP or MSTP.
Use the no variant of this command to disable the errdisable-timeout facility.
Syntax
spanning-tree errdisable-timeout enable
no spanning-tree errdisable-timeout enable
Default By default, the errdisable-timeout is disabled.
Mode Global Configuration
Usage The BPDU guard feature shuts down the port on receiving a BPDU on a
BPDU-guard enabled port. This command associates a timer with the feature such
that the port is re- enabled without manual intervention after a set interval. This
interval can be configured by the user using the spanning-tree errdisable-timeout
interval command.
Example
awplus# configure terminal
awplus(config)# spanning-tree errdisable-timeout enable
Related
Commands
show spanning-tree
spanning-tree errdisable-timeout interval
spanning-tree portfast bpdu-guard

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AlliedWare Plus AT-x230-10GP and is the answer not in the manual?

Allied Telesis AlliedWare Plus AT-x230-10GP Specifications

General IconGeneral
BrandAllied Telesis
ModelAlliedWare Plus AT-x230-10GP
CategorySwitch
LanguageEnglish

Related product manuals