EasyManua.ls Logo

D-Link DGS-6600-48TS

D-Link DGS-6600-48TS
972 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DGS-6604 m errdisable recovery
CLI Reference Guide
205
errdisable recovery
Use the errdisable recovery command to enable and configure the error
recovery function. Use the no command to disable the auto recovery for causes
or to return interval to default setting for causes.
errdisable recovery cause {all | loopback-detection} [interval SECONDS]
no errdisable recovery cause {all | loopback-detection} [interval]
Default Auto recovery is disabled for all causes
If enabled, the Interval is 300 seconds
Command Mode Global configuration
Usage Guideline A port can be put in error disabled state (an operational state that is similar to the
link-down state) by causes such as loopback detection.
A port in error disabled state can not transmit nor receive any packets.
An error disabled port can be either manual recovered or automatically restored
by using this command.
The user can enter shutdown and then no shutdown commands to recover an
interface manually from the error-disabled state.
If auto recovery is enabled for a specific cause, the port error disabled by that
caused will be auto recovered once the cause have timed out.
Example This example shows how to set the recovery timer to 200 seconds for port
loopback-detection.
Syntax Description
all Specifies the configure auto recovery for all causes.
loopback-detection Specifies the configure auto recovery of error report caused by loopback-
detection
interval SECONDS Specifies the time, in seconds, to recover the port from an error state caused by
the specified module. The valid value is 30 to 86400.
Switch# configure terminal
Switch(config)# errdisable recovery cause loopback-detection interval 200
Switch(config)# end

Table of Contents