DGS-6604 m show ddm configuration
CLI Reference Guide
593
Temperature Voltage Bias Current TX Power RX Power
Threshold (Celsius) (V) (mA) (mW) (mW)
------------ ------------ ------------ ------------ ------------ ----------
--
High Alarm - - - - -
High Warning - - - - -
Low Warning - - - - -
Low Alarm - - - - -
Interface eth3.25
===========================================================================
DDM state : Enabled
Shutdown : None
Temperature Voltage Bias Current TX Power RX Power
Threshold (Celsius) (V) (mA) (mW) (mW)
------------ ------------ ------------ ------------ ------------ ----------
High Alarm 75.000 3.630 10.500 1.4125 1.5849
High Warning 70.000 3.465 9.000 0.7079 0.7943
Low Warning 0.000 3.135 2.500 0.1862 0.1023
Low Alarm -5.000 2.970 2.000 0.0741 0.0407
Interface eth3.26
===========================================================================
DDM state : Enabled
Shutdown : None
Temperature Voltage Bias Current TX Power RX Power
Threshold (Celsius) (V) (mA) (mW) (mW)
------------ ------------ ------------ ------------ ------------ ----------
High Alarm 75.000 3.630 10.500 1.4125 1.5849
High Warning 70.000 3.465 9.000 0.7079 0.7943
Low Warning 0.000 3.135 2.500 0.1862 0.1023
Low Alarm -5.000 2.970 2.000 0.0741 0.0407