M4300 Series and M4300-96X Fully Managed Switches User Manual
The following table describes the nonconfigurable Stack Configuration fields.
The following table describes the nonconfigurable Stack Status information that is displayed.
Table 58. Stack Configuration
Field Description
Hardware Management
Preference
The hardware management preference of the switch. The hardware
management preference can be disabled or unassigned.
Standby Status Identifies the switch that is configured as the standby unit. The possible
values are as follows:
Cfg Standby. Indicates that the unit is configured as the standby unit.
The unit configured as the standby switch becomes the stack manager if
the current manager fails.
Opr Standby. Indicates that this unit is operating as the standby unit
and the configured standby unit is not part of the stack.
None.
The switch is not configured as the standby unit.
Switch Status The status of the selected unit.
The possible values are as follows:
OK. The
unit
is connected and works properly.
Unsupported. The type of inserted unit is not supported.
Code Mismatch. The firmware version is not identical to the master or
management unit.
Config Mismatch
.
The inserted device type is dif
ferent from the
configured devices.
Not Present.
The unit is not connected.
SDM Mismatch
. The SDM
template does not match.
Updating Code. A firmware
update is in progress.
STM Mismatch. The STM
template does not match.
Table 59. Stack Status nonconfigurable fields
Field Description
Hardware Management
Preference
The hardware management preference of the switch, which can be
disabled or unassigned.
Standby Status Identifies the switch that is configured as the standby unit:
Cfg Standby
. The
unit is configured as the standby unit. The unit
configured as the standby switch becomes the stack manager if
the current manager fails.
Opr Standby
.
This unit is operating as the standby unit and the
configured standby Unit is not part of the stack.
None.
The switch is not configured as the standby unit.

Table of Contents

Other manuals for NETGEAR M4300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR M4300 and is the answer not in the manual?

NETGEAR M4300 Specifications

General IconGeneral
ModelM4300
Form FactorRack-Mountable
LayerLayer 3
StackableYes
ManagedYes
MemoryVaries by model
Flash MemoryVaries by model
WarrantyLifetime
PortsVaries by model (24 or 48 ports)
PoEAvailable on some models
Port Speed10/100/1000 Mbps, 10Gbps on uplinks
Forwarding RateVaries by model
Jumbo Frame SupportYes
VLAN SupportYes
Quality of Service (QoS)Yes
Security FeaturesACLs, 802.1X
DimensionsVaries by model
WeightVaries by model
Operating Temperature0° to 50° C (32° to 122° F)
Power SupplyInternal
Uplink PortsVaries by model (SFP/SFP+ or 10G SFP+)