Configure System Information 
49
 M4300 Series and M4300-96X Fully Managed Switches User Manual
8.  For model M4300-96X, if you changed the settings, click the Apply button.
Your settings are saved.
The following table describes the nonconfigurable information in the Slot Configuration 
table.
The following table describes information in the Supported Card table.
Field Description
Slot The unit and slot number.
Status Indicates whether the slot is empty or full.
Power State For model M4300-96X only, the power state is always Enable.
For other models, the Power State column does not display.
Configured Card Description The description of the port card configured for the slot
Inserted Card Model ID The model ID of the port card plugged into the slot.
Inserted Card Description The description of the port card plugged into the slot.
Card Power Down If the value is True, the power state can be administratively enabled or 
disabled. If the value is False, the power state cannot be configured.
Card Pluggable If the value is True, the card can be administratively enabled or disabled. If 
the value is False, the administrative state cannot be configured.
PoE Capable Indicates whether a port card is PoE cable.
Field Description
Card Model The model ID of the supported port card.
Card Index The index assigned to the port card type.
Card Type The hardware type of the supported port card, which is assigned by the 
manufacturer
.
Card Descriptor The description of the supported port card, which includes the manufacturer 
product number and information about the number and speed of the 
supported interfaces.