Summary: New Features for R&S SMU200A Users
R&S
®
SMW200A
1188User Manual 1175.6632.02 ─ 16
Example:
To enable a 2x2 MIMO configuration, open the "System Configuration > Fading/Base-
band Configuration" dialog. Enable the following setting.
Figure A-1: System Configuration in the "Advanced Mode" (1x2x2 configuration)
1 = advanced mode, required for configuration of complex LxNxM MIMO scenarios
2 = current signal routing; 2x2 MIMO configuration
3 = separated and coupled baseband sources
4 = simplified preview diagram of the particular configuration
A.10 Info Manager and Remote Indication
●
The R&S SMW does not permanently display the "Info" line. It appears when an
event occurs.
A remote operation is indicated by:
●
Symbol displayed in the status bar.
●
Information on the used remote channels displayed in the taskbar.
A.11 Operating System
The R&S SMU is based on Microsoft Windows, the R&S SMW on Linux embedded.
Operating System