Remote Control Commands
R&S
®
SMW200A
959User Manual 1175.6632.02 ─ 16
Marker Commands
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:MODE <Mode>
Defines the signal for the selected marker output.
For detailed description of the regular marker modes, refer to "Marker Modes"
on page 235.
Parameters:
<Mode> UNCHanged | RESTart | PULSe | PATTern | RATio
UNCHanged
A marker signal as defined in the waveform file (tag 'marker
mode x') is generated.
*RST: UNCHanged
Example: see Example "Managing waveform files" on page 920
Manual operation: See "Marker Mode" on page 315
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:ONTime <OnTime>
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:OFFTime <OffTime>
Sets the number of samples in the ON and OFF periods.
*)
If R&S SMW-B9 is installed, the minimum marker duration depends on the sample/
symbol rate.
See "Marker Minimum Duration" on page 236.
Parameters:
<OffTime> integer
Range: 1 (R&S SMW-B10) / 16* (R&S SMW-B9) to
14913079
*RST: 1
Example: see Example "Managing waveform files" on page 920
Manual operation: See "Marker Mode" on page 315
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:PATTern <Pattern>
Defines the bit pattern used to generate the marker signal.
Parameters:
<Pattern> <64 bits pattern>
0 = marker off, 1 = marker on
*RST: #H2,2
Example: See Example "Managing waveform files" on page 920
Manual operation: See "Marker Mode" on page 315
SOURce Subsystem