Remote Control Commands
R&S
®
SMW200A
940User Manual 1175.6632.02 ─ 16
Manual operation: See "Next Segment Mode" on page 343
Multi-Segment Sequencing Commands
Required options
See Chapter 4.8.1, "Required Options", on page 324.
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:BLANk:APPend
<SampCount>, <Frequency>
Adds a blank segment to the multi-segment file.
Setting parameters:
<SampCount> float
Specifies the number of samples.
Range: 512 to 1E7
Increment: 1
*RST: 1000
<Frequency> float
Determines the clock rate.
Range: 400 Hz to depends on the installed options
Increment: 0.001
*RST: 1E8
Example: See Example "Creating a multi-segment waveform" on page 922
Usage: Setting only
Manual operation: See "Blank Segment" on page 334
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CATalog?
Queries the available configuration files in the default directory. See also Chap-
ter 4.8.2.3, "File Concept", on page 326.
Return values:
<Catalog> string
Example: see Example "Creating a multi-segment waveform" on page 922
Usage: Query only
Manual operation: See "Load List" on page 332
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CLOCk <Clock>
Defines the clock rate used for multi-segment waveform output if the clock mode is
USER.