Configuring the Internal Baseband Source
R&S
®
SMW200A
260User Manual 1175.6632.02 ─ 16
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:PULSe:FREQuency?
on page 1000
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:PATTern on page 1000
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:ONTime on page 999
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:OFFTime on page 999
Marker x Delay
Delays the marker signal at the marker output relative to the signal generation start.
Variation of the parameter "Marker x Delay" causes signal recalculation, regardless of
the indication "Current Range without Recalculation".
Remote command:
[:SOURce<hw>]:BB:DM:TRIGger:OUTPut<ch>:DELay on page 912
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:DELay on page 960
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:DELay on page 1000
4.5.2.3 Clock Settings
Access:
► Select "Baseband > Custom Dig Mod > Clock".
This tab provides access to the settings necessary to select and configure the clock
signal, like the clock source and clock mode.
Settings:
Clock Source...............................................................................................................260
Clock Mode................................................................................................................. 261
Measured External Clock............................................................................................261
Clock Source
Selects the clock source (see "Clock Signals" on page 230).
Selects the clock source.
●
"Internal"
The instrument uses its internal clock reference.
●
"External Local Clock"
The instrument expects an external clock reference at the local T/M/C connector.
"External Local Clock" requires R&S SMW-B10.
Common Functions and Settings in the Baseband Domain