EasyManua.ls Logo

Rohde & Schwarz SMW200A - Setting for Handling the Multi-Segment Files and Output File Settings

Rohde & Schwarz SMW200A
1312 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring the Internal Baseband Source
R&S
®
SMW200A
331User Manual 1175.6632.02 ─ 16
4. Select "Baseband > ARB > General".
The "Load Waveform" confirms that the current multi-segment file is loaded (file
name as defined with "Output File").
5. Select "Baseband > ARB > Trigger In (MSW)".
For a description of the provided settings, refer to Chapter 4.8.3.5, "Next Segment
Trigger In Settings", on page 342.
6. Select "Baseband > ARB > General > State > On" to process the configured multi-
segment waveform.
The remote commands required to define these settings are described in Chap-
ter 13.18.4.3, "SOURce:BB:ARBitrary Subsystem", on page 919.
Setting for Handling the Multi-Segment Files and Output File Settings................ 331
Segment Table......................................................................................................333
Level / Clock / Marker Settings............................................................................. 335
Multi-Segment Waveform Sequencing..................................................................337
Next Segment Trigger In Settings.........................................................................342
4.8.3.1 Setting for Handling the Multi-Segment Files and Output File Settings
Access:
1. Select "Baseband > ARB > General > Create Multi Segment".
The "General" tab comprises standard functions for file handling, like selecting and
loading of files, or determining the output file name.
2. Perform one of the following:
Select "New List" to create a multi-segment waveform file
Select "Load List" to load an existing one
3. Add a comment and select "Output File" to define the file name the multi-segment
waveform is created at.
Note: The provided settings depend on the current waveform.
The "Sequencing List" function for instance requires that:
Multi segment file is created, i.e. you have executed"Create Output File/
Create and Load Output File".
"Sequence Table" contains more than one segment.
Settings:
New List...................................................................................................................... 332
Load List......................................................................................................................332
Save List/Save List As................................................................................................ 332
Sequencing List...........................................................................................................332
Comment.....................................................................................................................332
Output file....................................................................................................................332
Create/Create and Load..............................................................................................333
Generating Multi-Segment Waveform Files