Remote Control Commands
R&S
®
SMW200A
833User Manual 1175.6632.02 ─ 16
// Response: MULT
SCONfiguration:OUTPut:MAPPing:BBMM2:MODE?
// Response: MULT
SCONfiguration:OUTPut:MAPPing:BBMM1:STReam1:STATe?
// Response: 1
SCONfiguration:OUTPut:MAPPing:BBMM1:STReam3:STATe?
// Response: 1
SCONfiguration:OUTPut:MAPPing:BBMM1:STReam5:STATe?
// Response: 1
SCONfiguration:OUTPut:MAPPing:BBMM1:STReam7:STATe?
// Response: 1
SCONfiguration:OUTPut:MAPPing:BBMM2:STReam2:STATe?
// Response: 1
SCONfiguration:OUTPut:MAPPing:BBMM2:STReam4:STATe?
// Response: 1
SCONfiguration:OUTPut:MAPPing:BBMM2:STReam6:STATe?
// Response: 1
SCONfiguration:OUTPut:MAPPing:BBMM2:STReam8:STATe?
// Response: 1
● Multi Instrument Configuration.............................................................................. 833
● Baseband and Fading Configuration.................................................................... 834
● I/Q Stream Mapping..............................................................................................840
● External RF and I/Q Instruments...........................................................................841
13.17.1 Multi Instrument Configuration
Option: R&S SMW-B9.
:SCONfiguration:MULTiinstrument:MODE........................................................................ 833
:SCONfiguration:MULTiinstrument:STATe........................................................................ 833
:SCONfiguration:MULTiinstrument:TRIGger:SYNChronization?.......................................... 834
:SCONfiguration:MULTiinstrument:MODE <MSMode>
Sets if the instrument works as master or as slave.
Parameters:
<MSMode> SLAVe | MASTer
*RST: MASTer
Example: See Example "Configuring master-slave mode" on page 828
Manual operation: See "Multi Instrument Trigger" on page 610
:SCONfiguration:MULTiinstrument:STATe <TriggerState>
Activates the selected mode.
SCONfiguration Subsystem