[:SOURce<hw>]:PULM:WIDTh <Width>
Sets the width of the generated pulse, that means the pulse length. It must be at least
20ns less than the set pulse period.
Parameters:
<Width> float
Range: 20E-9 to 100
Increment: 10E-9
*RST: 2E-6
Example: See Example "Perform pulse modulation" on page 881.
Manual operation: See "Pulse Width" on page 516
[:SOURce<hw>]:PULM:DOUBle:STATe
<State>
Provided for backward compatibility with former Rohde & Schwarz signal generators.
Works like the command [:SOURce<hw>]:PULM:MODE DOUBle.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
13.18.4 SOURce:BB Subsystem
This subsystem contains all commands for digital signal generation. It is divided into
several subsystems which are described separately.
SOURce:BB Subsystem General Commands...................................................... 886
SOURce:BB:DM Subsystem.................................................................................890
SOURce:BB:ARBitrary Subsystem.......................................................................919
Waveform, Data and List Format.......................................................................... 961
SOURce:BB:MCCW Subsystem...........................................................................983
SOURce:AWGN Subsystem...............................................................................1001
SOURce:BB:IMPairment Subsystem..................................................................1011
SOURce:BB:GRAPhics Subsystem....................................................................1015
SOURce:BB:MEASurement Subsystem.............................................................1019
SOURce:BB:PROGress Subsystem General Commands..................................1024
13.18.4.1 SOURce:BB Subsystem General Commands
The following section describes the commands for setting the frequency shift and the
phase offset for the signal at the output of the "Baseband" and "BB Input" blocks.
Suffixes in the keywords ENTity<ch> and SOURce<hw>
You can address multiple entities configurations by using the SCPI commands starting
with the keyword SOURce or the alias commands starting with the keyword ENTity.
SOURce Subsystem

Table of Contents

Related product manuals