Configuring the Internal Baseband Source
R&S
®
SMW200A
276User Manual 1175.6632.02 ─ 16
State Modulation <=> CW Switching
Enables/disables switching between the digitally modulated and an unmodulated (CW)
signal.
Remote command:
[:SOURce<hw>]:BB:DM:SWITching:STATe on page 902
4.6.3.5 Filter Settings
Access:
► Select "Baseband > Custom Dig Mod > Filter".
This tab provides access to the filter settings, like filter type and if available further filter
settings. A simplified diagram shows the filter characteristic of the selected filter.
This section focuses on the available settings. For background information on how the
settings affect the signal and the filter characteristics, refer to Chapter 4.5.1.6, "Suppor-
ted Baseband Filters", on page 248.
Settings:
Filter............................................................................................................................ 276
Filter Parameter.......................................................................................................... 277
Cutoff Frequency Factor............................................................................................. 277
Bandwidth................................................................................................................... 277
Load User Filter...........................................................................................................277
Filter
Selects the baseband filter.
Refer to Chapter 4.6.5.3, "Predefined Baseband Filters", on page 297 for overview of
the available filter types, their filter shapes and filter parameters.
Remote command:
[:SOURce<hw>]:BB:DM:FILTer:TYPE on page 898
Generating Custom Digital Modulated Signals