Remote Control Commands
R&S
®
SMW200A
893User Manual 1175.6632.02 ─ 16
SOURce:BB:DM:TRIGger:SEQuence AAUTo
SOURce:BB:DM:TRIGger:SOURce INTernal
SOURce:BB:DM:STAT ON
SOURce:BB:DM:TRIGger:EXEC
Example: Enable power ramping
The following example lists the provided commands
SOURce:BB:DM:PRAMp:SOURce INTernal
SOURce:BB:DM:PRAM:SHAP COS
SOURce:BB:DM:PRAMp:TIME 5
SOURce:BB:DM:PRAMp:RDELay 0
SOURce:BB:DM:PRAMp:FDELay -1
SOURce:BB:DM:PRAMp:ATTenuation 10
SOURce:BB:DM:PRAMp:BBONly:STATe ON
SOURce:BB:DM:PRAMp:STATe ON
General Commands
[:SOURce<hw>]:BB:DM:STATe <State>
Enables/disables digital modulation. Switching on digital modulation turns off all the
other digital standards in the same signal path.
Parameters:
<State> 0 | 1 | OFF | ON
*RST:  0
Example:  See Example "Performing general tasks" on page 891
Manual operation:  See "State" on page 266
[:SOURce<hw>]:BB:DM:PRESet
Sets the default settings for digital modulation (*RST values specified for the com-
mands).
Not affected is the state set with the command SOURce<hw>:BB:DM:STATe
Example: 
See Example "Performing general tasks" on page 891
Usage:  Event
Manual operation:  See "Set To Default" on page 266
[:SOURce<hw>]:BB:DM:SRATe <SRate>
Sets the symbol rate in Hz/kHz/MHz or Symb/s, kSymb/s and MSymb/s.
SOURce Subsystem