Remote Control Commands
R&S
®
SMW200A
864User Manual 1175.6632.02 ─ 16
Parameters:
<Impedance> G1K | G50 | G10K
G10K
Provided only for backward compatibility with other R&S signal
generators.
The R&S SMW accepts this value and maps it automatically to
G1K.
*RST: G1K
Manual operation: See "Impedance Clock/Trigger Input" on page 677
[:SOURce<hw>]:INPut:TM:CLOCk:SLOPe
<Slope>
Sets the polarity of the active slope of an externally applied clock signal.
Suffix:
SOURce<hw>
.
1 | 2
Determines the baseband the connectors belong to, where:
SOURce1 = Baseband A/C and
SOURce2 = Baseband B/D
Parameters:
<Slope> NEGative | POSitive
*RST: POSitive
Manual operation: See "Clock Input Slope" on page 677
[:SOURce<hw>]:INPut:TM:TRIGger:SLOPe <Slope>
Sets the polarity of the active slope of an externally applied trigger signal.
Suffix:
SOURce<hw>
.
1 | 2
Determines the baseband the connectors belong to, where:
SOURce1 = Baseband A/C and
SOURce2 = Baseband B/D
Parameters:
<Slope> NEGative | POSitive
*RST: POSitive
Manual operation: See "Trigger Input Slope" on page 677
13.18.2 SOURce:BBIN Subsystem
The SOURce:BBIN subsystem contains the commands for setting the external digital
baseband signal.
In Standard mode, the external baseband signal A can be routed to path A, path B, or
both paths. The external baseband signal B can be routed to path B only.