Signal Routing and System Configuration
R&S
®
SMW200A
192User Manual 1175.6632.02 ─ 16
How to Connect and Configure External Instruments...........................................198
How to Generate a 2x8 MIMO Signal for BS Tests...............................................207
How to Generate a 8x8 MIMO Signal with Two R&S SMW..................................209
How to Connect an R&S
®
CMW500 for Fading Applications.................................214
How to Apply an External Digital Baseband Signal.............................................. 215
How to Connect an R&S EX-IQ-BOX....................................................................218
3.9.1 Finding Out the Suitable Configuration for Your Test Situation
For conceptual information on the workflow, refer to "General workflow for finding out
the suitable system configuration for a current use case" on page 123.
1. Select a system configuration form the test cases listed in Table 3-1.
The table provides a cross-reference between a test scenario and the required
configuration.
2. Select "Taskbar > System Configuration > Fading/Baseband Settings":
Follow the instructions in "To simulate complex MxN MIMO scenarios using the
"Fading and Baseband Configuration" settings" on page 193.
Observe the preview diagram in the "Fading/Baseband Settings" dialog.
This diagram provides a short description and an example of the common applica-
tion or test scenario of the selected configuration.
For description of the further steps, see:
Chapter 3.9.3, "How to Define the MIMO Scenario", on page 193
Chapter 3.9.4, "How to Route the I/Q Streams to the Output Interfaces",
on page 196
See also:
Chapter 3.9.5, "How to Cable the Instruments in MIMO Test Setups",
on page 197
Chapter 3.9.6, "How to Connect and Configure External Instruments",
on page 198
3.9.2 How to Find Out where the Input/Output Interface Is Located
See:
"To find out the correct connector" on page 192
"To find out the connector's direction" on page 193
To find out the correct connector
1. Select "Taskbar > System Configuration > External RF and I/Q".
2. In the overview table, navigate to the connector an external instrument has to be
connected to (e.g. "BBMM 1").
Select "External Instruments > Config".
How to Connect External Instruments and Configure the Signal Flow