Remote Control Commands
R&S
®
SMW200A
834User Manual 1175.6632.02 ─ 16
Parameters:
<TriggerState> 0 | 1 | OFF | ON
*RST:  0
Example:  See Example "Configuring master-slave mode" on page 828
Manual operation:  See "State" on page 610
:SCONfiguration:MULTiinstrument:TRIGger:SYNChronization?
Queries if synchronization is achieved.
Return values: 
<SyncSTate> SYNC | NOSYnc
*RST:  NOSYnc
Example:  See Example "Configuring master-slave mode" on page 828
Usage:  Query only
Manual operation:  See "Synchronisation State" on page 610
13.17.2 Baseband and Fading Configuration
Option: R&S SMW-B10.
:SCONfiguration:PRESet................................................................................................ 834
:SCONfiguration:MODE..................................................................................................834
:SCONfiguration:OUTPut:MODE..................................................................................... 835
:SCONfiguration:FADing.................................................................................................835
:SCONfiguration:MIMO:SUBSet.......................................................................................836
:SCONfiguration:BASeband:SOURce...............................................................................839
:SCONfiguration:DUPLicate[:STReam].............................................................................839
:SCONfiguration:APPLy..................................................................................................839
:SCONfiguration:PRESet
Presets the signal routing in the baseband section and the fading configuration to the
default state.
Example: 
see Example "Distributing the I/Q streams to the output connec-
tors (advanced configuration)" on page 826
Usage:  Event
Manual operation:  See "Set to Default" on page 140
:SCONfiguration:MODE <Mode>
Switches between the operating modes.
 
SCONfiguration Subsystem