Configuring the Internal Baseband Source
R&S
®
SMW200A
345User Manual 1175.6632.02 ─ 16
Execute Next Segment
For "Next Segment Source = Internal", triggers manually switch over to the subsequent
segment in the multi-segment file. The subsequent segment can be any segment
within the multi-segment file and is defined by the parameter "Segment"
This parameter is disabled, if a sequencing play list is enabled.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:NEXT:EXECute on page 937
Sequencing List
Opens a dialog box for defining the “play lists”, see Chapter 4.8.3.4, "Multi-Segment
Waveform Sequencing", on page 337.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:SEQuence:SELect on page 937
Trigger Example
Displays an example of a multi-segment waveform. The currently enabled trigger and
next segment mode are considered. After the instrument is switched on, the graph of
the last loaded waveform is displayed.
Note: The curves plotted in this dialog box are textbook examples, "not measured"
waveforms. They are intended to visualize the trigger and next segment settings more
clearly.
Remote command:
n.a.
4.8.4 How to Create and Work with the Multi-Segment Waveform Files
This section provides step-by-step instructions on how to configure and use the multi-
segment settings. The Figure 4-21 shows the essential stages of multi-segment wave-
form configuration, together with the corresponding user interface dialogs and if appli-
cable, the corresponding file extensions. Perform the necessary settings, enable the
signal generation, and provide trigger signal.
Figure 4-21: Basic workflow for generation of multi-segment waveforms
Generating a multi-segment waveform file (basic workflow)
1. In the "ARB > Multi Segment > General" dialog, select "New List" to create empty
list.
2. Use the "ARB: Multi Segment > Segment Table > Append" function to add two or
more waveform files.
Generating Multi-Segment Waveform Files