Remote Control Commands
R&S
®
SMW200A
937User Manual 1175.6632.02 ─ 16
[:SOURce<hw>]:BB:ARBitrary:WSEGment:NEXT:EXECute
Triggers manually switchover to the subsequent segment in the multi-segment file.
This command is disabled, if a sequencing play list is enabled.
Example: See Example "Configuring the output order of the segments"
on page 924
Usage: Event
Manual operation: See "Execute Next Segment" on page 345
[:SOURce<hw>]:BB:ARBitrary:WSEGment:NEXT:SOURce <Source>
Selects the next segment source.
Parameters:
<Source> INTernal | NSEGM1 | NSEGM2
*RST: INTernal
Example: see Example "Configuring the output order of the segments"
on page 924
Options: NSEGM1|NSEGM2 require R&S SMW-B10
Manual operation: See "Next Segment Source" on page 344
[:SOURce<hw>]:BB:ARBitrary:WSEGment:LMODe <LevelMode>
Sets how the segments are leveled.
Parameters:
<LevelMode> HIGHest | UNCHanged
*RST: HIGHest
Example:
:SOURce1:BB:ARBitrary:WSEGment:LMODe HIGHest
Manual operation: See "Level Mode" on page 344
[:SOURce<hw>]:BB:ARBitrary:WSEGment:SEQuence:SELect <Filename>
Selects the sequencing list (files with extension *.wvs)
Parameters:
<Filename> string
Example: see Example "Using the ARB sequencer" on page 925
Manual operation: See "New/Load Sequencing List" on page 339
SOURce Subsystem