Remote Control Commands
R&S
®
SMW200A
1089User Manual 1175.6632.02 ─ 16
[:SOURce<hw>]:NOISe:DISTribution <Distribution>
Sets the distribution of the noise power density.
Parameters:
<Distribution> GAUSs | EQUal
*RST: GAUSs
Example: See Example "Configuring the noise generator" on page 1088.
Manual operation: See "Distribution" on page 505
[:SOURce<hw>]:NOISe:LEVel<ch>:RELative?
Queries the level of the noise signal per Hz in the total bandwidth.
Return values:
<Relative> float
Range: -149.18 to -52.67
Increment: 0.1
*RST: -69.84
Example: See Example "Configuring the noise generator" on page 1088.
Usage: Query only
Manual operation: See "Noise Density" on page 506
[:SOURce<hw>]:NOISe:LEVel<ch>[:ABSolute]?
Queries the level of the noise signal in the system bandwidth within the enabled band-
width limitation.
Return values:
<Absolute> float
*RST: 3.84 MHz
Example: See Example "Configuring the noise generator" on page 1088.
Usage: Query only
Manual operation: See "Noise Level" on page 506
13.18.13 SOURce:PGEN Subsystem
The PGEN subsystem contains the commands for setting output of the pulse modula-
tion signal.
SOURce Subsystem