Signal Routing and System Configuration
R&S
®
SMW200A
187User Manual 1175.6632.02 ─ 16
●
V
offset
is the offset between inverting and non-inverting output as set with the
parameter Offset (EMF)
For more information, see data sheet.
Related settings
●
See Chapter 3.8.1, "General Analog I/Q Output Settings", on page 187
●
See Chapter 5.3, "Impairing the Signal", on page 406.
See user manual R&S
®
SMW-K540, R&S
®
SMW-K541 Envelope Tracking and AM/AM,
AM/PM Predistortion.
3.8.1 General Analog I/Q Output Settings
Access:
► Select "I/Q Analog > I/Q Analog Settings > General".
Settings:
State............................................................................................................................187
Set to Default.............................................................................................................. 187
Save/Recall.................................................................................................................188
RF Envelope............................................................................................................... 188
I/Q Output Type...........................................................................................................188
Mode........................................................................................................................... 189
I/Q Level Vp EMF........................................................................................................189
Couple I/Q Bias...........................................................................................................189
Bias (EMF).................................................................................................................. 189
Offset (EMF)................................................................................................................190
State
Enables/disables the analog I/Q output.
Note: By default, these output connectors are deactivated.
Remote command:
[:SOURce<hw>]:IQ:OUTPut:ANALog:STATe on page 1052
Set to Default
Calls the default settings. The values of the main parameters are listed in the following
table.
Parameter Value
"State" Not affected by the "Set to Default"
"RF Envelope" Off
I/Q Analog Output Settings