Signal Routing and System Configuration
R&S
®
SMW200A
164User Manual 1175.6632.02 ─ 16
4. Select "Check Connection".
The dialog is a graphical representation of the required connections and their sta-
tus. The connection status indication is color coded.
The dialog shows information on the following:
Connection check status
Signal connections status
Remote control connections status
Remote command:
:SCONfiguration:EXTernal:IQOutput<ch>:CONNections:CHECk?
on page 855
3.4.4 Overview
Access:
To display an interactive overview diagram of the current configuration, select
"System Configuration > Overview".
The overview tab shows information on the following:
Current stream mapping to the output interfaces, see Chapter 3.4.2, "I/Q
Stream Mapper Settings", on page 144.
Connected controller (external PC).
Connections for remote control of connected external I/Q and RF devices,
Chapter 3.4.3, "External RF and I/Q Settings", on page 147
Input and output signals, like:
LO coupling or used external reference frequency.
Connected external baseband source to the digital input interface.