Remote Control Commands
R&S
®
SMW200A
954User Manual 1175.6632.02 ─ 16
Trigger Commands
[:SOURce<hw>]:BB:ARBitrary[:TRIGger]:SEQuence <Sequence>
The command selects the trigger mode.
Parameters:
<Sequence> AUTO | RETRigger | AAUTo | ARETrigger | SINGle
*RST: AUTO
Example: See Example "Managing waveform files" on page 920
Manual operation: See "Trigger Mode" on page 255
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SOURce <Source>
Selects the trigger signal source and determines the way the triggering is executed.
Provided are:
●
Internal triggering by a command (INTernal)
●
External trigger signal via one of the local or global connectors
– EGT1|EGT2: External global trigger
– EGC1|EGC2: External global clock
– ELTRigger: External local trigger
– ELCLock: External local clock
●
Internal triggering by a signal from the other basebands (INTA|INTB)
●
In master-slave mode, the external baseband synchronization signal (BBSY)
●
OBASeband|BEXTernal|EXTernal: Setting only
Provided only for backward compatibility with other Rohde & Schwarz signal gener-
ators.
The R&S SMW accepts these values and maps them automatically as follows:
EXTernal = EGT1, BEXTernal = EGT2, OBASeband = INTA or INTB
(depending on the current baseband)
Parameters:
<Source> INTB | INTernal | OBASeband | EGT1 | EGT2 | EGC1 | EGC2 |
ELTRigger | INTA | ELCLock | BEXTernal | EXTernal | BBSY
*RST: INTernal
Example: See Example "Managing waveform files" on page 920
Options: ELTRigger|ELCLock require R&S SMW-B10
BBSY require R&S SMW-B9
Manual operation: See "Trigger Source" on page 256
[:SOURce<hw>]:BB:ARBitrary:TRIGger:RMODe?
Queries the status of waveform output.
SOURce Subsystem