EasyManua.ls Logo

Rohde & Schwarz SMW200A - Page 361

Rohde & Schwarz SMW200A
1312 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring the Internal Baseband Source
R&S
®
SMW200A
346User Manual 1175.6632.02 ─ 16
3. In the "ARB: Multi Segment > Level/Clock/Marker" dialog, adjust the "Level",
"Clock", and "Segment Marker" settings.
4. Select the "ARB > Multi Segment > General > Output File" and enter file name.
5. Select "ARB > Multi Segment > General > Save List" to store the configuration file.
6. Select "ARB > Multi Segment > General > Create" or "Create and Load" to create
and load the multi-segment waveform.
7. Select "ARB > Multi Segment > General > State > On".
Tip: Try out the built-in tutorial.
The following description emphasizes on the settings required to fulfill the particular
task or achieve the desired performance; standard basic settings are not discussed.
All provided examples use the example segment sequence as shown on Figure 4-22.
Figure 4-22: Example: multi-segment sequence with marker signals
See how to:
"To apply a manual segment switch to the output segments in the required order"
on page 346
"To generate a multi-segment signal without signal interruptions" on page 348
"To enable an external triggering for high-speed switch over" on page 348
"To configure a multi-segment sequence using the play list function" on page 349
"To add marker signals" on page 350
To apply a manual segment switch to the output segments in the required order
When testing DUTs using different test signals, it may be necessary to switch dynami-
cally and flexibly between any of the test signals, for instance depending on the out-
come of the previous test. The following settings enable flexible dynamic switch over
between the segments in a multi-segment waveform.
Generating Multi-Segment Waveform Files