Remote Control Commands
R&S
®
SMW200A
863User Manual 1175.6632.02 ─ 16
Parameters:
<Slope> NEGative | POSitive
*RST: POSitive
Manual operation: See "Symbol Clock Slope/Clock Slope" on page 271
[:SOURce]:INPut:USER:TRIGger:SLOPe <Slope>
Sets the polarity of the active slope of an applied instrument trigger.
Parameters:
<Slope> NEGative | POSitive
*RST: POSitive
Example: See Example "Global connectors settings configuration"
on page 857
Manual operation: See "Trigger Input Slope" on page 674
[:SOURce<hw>]:INPut:TM:CLOCk:LEVel <Level>
[:SOURce<hw>]:INPut:TM:TRIGger:LEVel <Level>
Sets the high/low threshold in volts for the trigger and clock signal inputs of the base-
band section.
Suffix:
SOURce<hw>
.
1 | 2
Determines the baseband the connectors belong to, where:
SOURce1 = Baseband A/C and
SOURce2 = Baseband B/D
Parameters:
<Level> float
Range: 0.3 to 2
Increment: 0.1
*RST: 1
Manual operation: See "Threshold Clock/Trigger Input" on page 677
[:SOURce<hw>]:INPut:TM:CLOCk:IMPedance <Impedance>
[:SOURce<hw>]:INPut:TM:TRIGger:IMPedance <Impedance>
Selects the input impedance for the external trigger/clock inputs.
Suffix:
SOURce<hw>
.
1 | 2
Determines the baseband the connectors belong to, where:
SOURce1 = Baseband A/C and
SOURce2 = Baseband B/D
SOURce Subsystem