Remote Control Commands
R&S
®
SMW200A
885User Manual 1175.6632.02 ─ 16
[:SOURce]:PULM[:INTernal][:TRAin]:TRIGger:IMMediate
[:SOURce<hw>]:PULM:STATe <State>
Activates pulse modulation.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example: See Example "Perform pulse modulation" on page 881.
Manual operation: See "State" on page 513
[:SOURce<hw>]:PULM:TRIGger:MODE <Mode>
Selects a trigger mode - auto, external, external single or external gated - for generat-
ing the modulation signal.
Parameters:
<Mode> AUTO | EXTernal | EGATe | ESINgle
*RST: AUTO
Example: See Example "Perform pulse modulation" on page 881.
Manual operation: See "Trigger Mode" on page 516
[:SOURce<hw>]:PULM:TRIGger:EXTernal:IMPedance <Impedance>
Sets the impedance for the external pulse trigger.
Parameters:
<Impedance> G50 | G10K
*RST: G50
Example: See Example "Perform pulse modulation" on page 881.
[:SOURce<hw>]:PULM:TTYPe <Source>
Sets the transition mode for the pulse signal.
Parameters:
<Source> SMOothed | FAST
SMOothed
flattens the slew rate, resulting in longer rise/fall times.
FAST
enables fast transitions with shortest rise and fall times.
*RST: FAST
Example: See Example "Perform pulse modulation" on page 881.
Manual operation: See "Transition Type" on page 514