[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:PATTern <Pattern>
Defines the bit pattern used to generate the marker signal.
Parameters:
<Pattern> <32 bit pattern>
0 = marker off, 1 = marker on
*RST: 0
Example: See "Programming Examples" on page 983
Manual operation: See "Marker Mode" on page 259
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:PULSe:DIVider
<Divider>
Sets the divider for pulse marker mode.
*)
If R&S SMW-B9 is installed, the minimum marker duration depends on the sample/
symbol rate.
See "Marker Minimum Duration" on page 236.
Parameters:
<Divider> integer
Range: 2 (R&S SMW-B10) / 32* (R&S SMW-B9) to 1024
*RST: 2
Example: See "Programming Examples" on page 983
Manual operation: See "Marker Mode" on page 259
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:PULSe:FREQuency?
Queries the pulse frequency of the pulsed marker signal.
Return values:
<Frequency> float
Increment: 1E-3
Example: see "Programming Examples" on page 983
Usage: Query only
Manual operation: See "Marker Mode" on page 259
[:SOURce<hw>]:BB:MCCW:TRIGger:OUTPut<ch>:DELay <Delay>
Defines the delay between the signal on the marker outputs and the start of the sig-
nals, expressed as number of samples.
SOURce Subsystem